Microinverter HMS-400
Download Datasheet Microinverter HMS-400
Description
With the output power up to 500 VA, Hoymiles new microinverter HMS-500 series rank among the highest for 1-in-1 microinverters.
All of these models listed are equipped with reactive power control and can meet the requirements of EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, etc.
The new Sub-1G wireless solution enables more stable communication under various environmental conditions.
Features
High-powered microinverter for 1-in-1 with output power up to 500 VA
With Reactive Power Control, compliant with EN 50549-1:2019, VDE-AR-N 4105:2018, VFR2019, etc.
Safer for rooftop solar stations with rapid shutdown compliance and isolated transformer
Connected to one panel, flexible for various applications
Sub-1G wireless solution allows stable communication with Hoymiles gateway DTU
Dimensions: 182 × 164 × 30mm
Rated output power: 400VA
Max. input voltage: 65V
Commonly used module power: 320W to 540W+
Max. input current: 14A
MPPT voltage range: 16V–60V
Number of MPPTs: 1
Number of modules connected: 1
Delivery in Europe 3 - 5 working days
Hoymiles Microinverter HMS-400
Technical features
Model HMS-400-1T
Input Data (DC)
Commonly used module power (W): 320 to 540+
Maximum input voltage (V): 65
MPPT voltage range (V): 16–60
Start-up voltage (V): 22
Maximum input current (A): 14
Maximum input short circuit current (A): 25
Output Data (AC)
Rated output power (VA): 400
Rated output current (A): 1.74
Nominal output voltage/range (V)1: 230/180–275
Nominal frequency/range (Hz)1: 50/45–55
Power factor (adjustable): > 0.99 default / 0.8 leading…0.8 lagging
Total harmonic distortion: < 3%
Maximum units per 10AWG branch2: 18
Maximum units per 12AWG branch2: 11
Efficiency
CEC peak efficiency: 96.7%
Nominal MPPT efficiency: 99.8%
Night power consumption (mW): < 50
Mechanical Data
Ambient temperature range (℃): -40 to +65
Dimensions (W × H × D mm):: 182 × 164 × 30
Weight (kg): 1.75
Enclosure rating: Outdoor-IP67 (NEMA 6)
Cooling: Natural convection-No fans
Features
Communication: Sub-1G
Type of isolation: Galvanically Isolated HF Transformer
Monitoring: Hoymiles S-Miles Cloud3
Compliance: EN 50549-1: 2019, VDE-AR-N 4105: 2018, VFR2019, IEC/EN 62109-1/-2,IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3
*1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System